期刊文献+

燃煤机组电动给水泵振动故障 原因分析与整改措施 预览

Cause Analysis and Solution of Vibration Fault of Motor-driven Feed Water Pump for Coal-fired Unit
在线阅读 免费下载
收藏 分享 导出
摘要 电动给水泵是火电燃煤机组给水系统的重要附属机械,液力耦合器连接电动机与给水泵,传递驱动,调节转速.某项目给水系统设备发生振动故障,给水泵驱动端振动超标,呈周期性波动.采用因果分析图法逐级分解查找原因,得出导致给水泵振动故障的直接原因.结合现场实际,提出对应整改措施,给出相关建议,以利改善设备、优化设计. Electric feed water pump is an important accessory machinery of the feed water system of the coal-fired power plant.The hydraulic coupler connects the motor and the feed water pump,and transfers the drive to regulate the speed.The feed water system equipment of a project has vibration fault,the vibration of the pump drive end exceeds the standard,showing periodic fluctuation.Causal analysis chart method was used to decompose and find out the causes step by step,and the direct causes of vibration failure of feed pump were obtained.Combined with the actual situation,the corresponding corrective measures were put forward,and some related proposals were given to improve equipment and optimize design.
作者 董浩勤 DONG Haoqin(Shanghai Power Supervision and Consultancy Co.,Ltd.,Xuhui District,Shanghai 200031,China)
出处 《发电技术》 2019年第S1期73-77,共5页 Power Generation Technology
关键词 燃煤机组 电动给水泵 液力耦合器 振动故障 coal-fired unit electric feed water pump hydraulic coupler vibration fault
作者简介 董浩勤(1973),男,高级工程师,主要从事电力工程监理、项目管理工作,396129170@qq.com。