凝结水精处理混床周期制水量偏低原因分析及处理 预览 被引量:4

Low periodic water production of condensate polishing mixed beds in a power plant:reason analysis and treatment
在线阅读 下载PDF
收藏 分享 导出
摘要 安徽某发电厂不同机组凝结水精处理混床氢型周期制水量存在差异,部分混床制水量明显低于理论值.检查发现精处理混床布水水帽内树脂污堵、阳再生塔内树脂混合不均及树脂在混床内发生二次分层是造成问题的主要原因.通过对再生工艺进行优化调整和阳再生塔顶部排气管道的改造,混床的制水量提高至15万t以上,基本接近理论值. Deviation exists in periodic water production of different condensate polishing(CP)mixed beds in a power plant,and the periodic water production of parts of the CP mixed beds was obviously low than the theoretical value.Experiments revealed that the main reasons for this problem were as follows:the inlet strainers of the CP mixed beds were blocked by resins,the resin was irregularly mixed in cation regeneration tank(CRT),and secondary stratification of the resin occurred in the PC mixed beds.By optimization on regeneration process and transformation of the exhaust duct on top of the CRT,both the periodic water production of two beds was increased to above 1.5×105 tons,which was close to the theoretical value.
作者 周仲康 郑敏聪 杨浩 金浩 李建华 孙玉忠 韩永霞 ZHOU Zhongkang[1] ZHENG Mincong[1] YANG Hao[2] JIN Hao[3] LI Jianhua[1] SUN Yuzhong[4] HAN Yongxia[5]
出处 《热力发电》 北大核心 2013年第11期共3页 Thermal Power Generation
关键词 凝结水 精处理 混床 周期制水量 树脂 再生 condensate water CP mixed bed cycle water production resin regeneration