百万千瓦级压水堆核电厂蒸汽发生器汽水分离装置热态验证试验 预览 被引量:6

Proof Test in Hot Condition on Steam Separation Device in Steam Generator for 1000MW PWR Nuclear Power Plant
在线阅读 下载PDF
收藏 分享 导出
摘要 对百万千瓦级压水堆核电厂蒸汽发生器汽水分离装置水-空气冷态试验确定的最佳结构进行了实际核电厂运行参数条件下的水-蒸汽热态验证试验,与国外先进结构汽水分离装置试验体在热态试验条件下的性能进行了对比。结果表明.在正常运行条件下,研制的汽水分离装置试验体出口蒸汽湿度(上携带)为0.0021%,远小于百万千瓦级压水堆核电厂蒸汽发生器设计规定的0.1%的湿度指标,其在恶劣工作条件下的汽水分离性能仍满足设计要求,并优于国外先进结构汽水分离装置试验体。 Steam-water proof test under nuclear power plant operation condition on the steam separation devices in steam generator for 1000MW PWR nuclear power plant has been conducted. The test result indicates that the steam humidity (carryover) in outlet of the steam separation device with optimized design features obtained by previous air-water screening test in cold condition is 0.0021% under nuclear power plant operation condition, which is less than the standard steam humidity (0.1%) required by the design of steam generator for 1000MW PWR nuclear power plant. Its performance under severe condition meets the design demand, and it is better than that of the advanced steam separation devices in other countries.
作者 陈军亮 薛运奎 王先元 程慧平 刘鸿运 巴长喜 左超平 CHEN Jun-liang, XUE Yun-kui, WANG Xian-yuan, CHENG Hui-ping, LIU Hong-yun, BA Chang-xi, ZUO Chao-ping ( 1. Harbin Engineering University, 150001, China; 2. Research Institute of Nuclear Power Operation. Wuhan, Hubei 430074, China )
出处 《核动力工程》 EI CAS CSCD 北大核心 2006年第3期 61-66,共6页 Nuclear Power Engineering
关键词 汽水分离器 干燥器 上携带 允许蒸汽负荷 Steam separator, Dryer, Carryover, Permission steam load
作者简介 陈军亮(1966-)。男.研究员级高工.在读博士研究生。现从事核设备研究设计工作。 薛运奎(1940-),男.研究员级高工。1962年毕业于西安交通大学锅炉制造专业。现从事核设备研究设计工作。 王先元(1963-).男.研究员级高工。1985年毕业于西安交通大学应用力学专业。现从事核设备研究设计、在役检查及维修、设备老化管理工作。
  • 相关文献

参考文献1

二级参考文献1

共引文献8

同被引文献47

引证文献6

二级引证文献11

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈
新型冠状病毒肺炎防控与诊疗专栏