期刊文献+

动态比较法确定机组的最优组合 预览 被引量:22

Optimal Generation Unit Commitment by Dynamic Comparing
在线阅读 下载PDF
收藏 分享 导出
摘要 本文提出了一种确定机组最优组合的新方法-动态比较法。该方法根据优先次序确定递增机组,进而确定机组最优递增负荷,再根据负荷曲线确定机组的最优开、停机时刻。其计算方法非常简单,计算速度快。用C语言编制了程序,对四种算例进行了计算,结果表明该方法具有较好的实用性。 A new method for the Generation Unit Commitment is presented in this paper-dynamic comparing. With this method,progressively increasing Generation Unit is determined by taking precedence. Go further optimal progressively increasing Load can be obtained. The optimization of start-up and shutdown off Generation Unit is achieved according to the loading curve. This method is simple and in quick calculation. The programming is compiled in the TURBO C language. Four examples tests have carried out to show the validity of the algorithm.
作者 王剑奇 张伯明 赵子臣 Wang Jianqi(Taiyuan Institute of Electric Power China 030013)Zhang Boming; Zhao Zichem(Tsinghua University Beijing 100085 China)
出处 《中国电机工程学报》 EI CSCD 北大核心 1996年第4期 254-256,共3页 Proceedings of the CSEE
关键词 机组组合 动态比较法 发电机组 unit comiitment dynamic comparing optimal progressing increasing load