期刊文献+

600MW汽轮发电机组无电动给水泵启动 预览 被引量:5

Starting Without Motor Driven Feed Pump of a 600 MW Power Generating Set
在线阅读 下载PDF
分享 导出
摘要 介绍了嘉兴发电厂600MW汽轮发电机组无电动给水泵启动的论证、准备与实施过程,强调了启动过程中的关键控制点,交待了启动前后的注意事项。由汽动给水泵实现汽轮发电机组启动的事实进一步说明,作为一种非设计启动方式,它的使用增强了机组启动灵活性,安全可靠。 The justification for starting without motor driven feed pump of Jiaxing Power Plant's 600MW generating set is explained, together with a description of required preparations and the following execution, simultaneously stressing the importance of taking hold of key points, and pointing out items to be heeded before and after start. The successfully effectuated starting with the steam driven feed pump shows that, though not been considered in the design, it raises the starting manageability of the set and thus is, to a certain extent, worthy of being popularized.
作者 顾伟飞 樊印龙 钱晓峰 张宝 GU Wei-fei , FAN Yin-long , QIAN Xiao-feng , ZHANG Bao (1. Jiaxing Power Co. Ltd., Jiaxing 314201, China; 2.Zhejiang Province's Power Testing & Research Institute, Hangzhou 310014, China)
出处 《发电设备》 2006年第5期 345-347,共3页 Power Equipment
关键词 能源与动力工程 汽轮发电机组 辅助蒸汽 汽动给水泵 调试 energy and power engineering power set auxiliary steam steam driven feed pump adjustment
作者简介 顾伟飞(1973-),男,工程师,主要从事大型火电机组运行方面的技术工作。