期刊文献+

聚类分区算法在新疆电网的应用 预览 被引量:4

Clustering area partition method applied to Xinjiang power network
在线阅读 下载PDF
收藏 分享 导出
摘要 为了提高新疆电网的安全稳定水平,实现新疆电网调度运行无功电压在线控制及智能化调度的目标,开发并研制新疆电网的自动电压控制(AVC)系统显得十分必要,而实现AVC首先要解决的关键问题是对电力系统进行分区。介绍了一种基于无功源空间的聚类分区算法,并将其成功地应用到新疆电网,经过验证,采用该分区算法得到的分区结果是合理的。 For enhancing the security stability of Xinjiang Power Network and carrying out intelligence of power grid's dispatching system, it is necessary to develop the Automatic Voltage Control(AVC)of Xinjiang Power Network. The key is to partition the whole network into strongly connected sub-network. In this paper, a clustering area partition method based on clustering analysis in MVAR control space is brought forword and applied to the Xinjiang Power Network .A reasonable partition result is gained.
作者 李江 晁勤 常喜强 宋联庆 LI Jiang, CHAO Qin, CHANG Xi-qiang , SONG Lian-qing ( 1.Xinjiang Changji Electric Power Bureau,Changji 831100,China; 2. College of Electric Engineering Science, Xinjiang University, Urumqi 830000,China; 3.Xinjiang Electric Power Corporation, Urumqi 830000,China; 4.Water and Electricity Department of Petrochina Tuha Oilfield Company, Shanshan 838202,China)
出处 《电力系统保护与控制》 EI CSCD 北大核心 2009年第6期 57-59,72,共4页 Power System Protection and Control
基金 新疆维吾尔自治区自然科学基金项目(200421127) 新疆教育厅重点项目(XJEDU2005101)
关键词 AVC 电压分区 聚类分析 新疆电网 AVC voltage area partition clustering analysis Xinjiang power network
作者简介 李江(1974-),男,硕士,助理工程师,从事电力系统运行与分析工作;E—mait:lijiang19740108@126.com. 晁勤(1959-),女,教授,博士生导师,研究方向为电力系统综合自动化; 常喜强(1975一),男,工程师,从事电力系统运行与分析工作。
  • 相关文献

参考文献4

二级参考文献21

  • 1郭庆来,孙宏斌,张伯明,李钦,刘崇茹,李尹,杨志新,王小英,李海峰.江苏电网AVC主站系统的研究和实现[J].电力系统自动化,2004,28(22):83-87. 被引量:90
  • 2HANJia-wei KAMBERM.数据挖掘概念与技术[M].北京:机械工业出版社,2001.151-161. 被引量:4
  • 3Francisco Castro, Gabriel Llort, Michele Pescina. Reliability Improvement of the Guri Hydroelectric Power Plant Computer Control System AGC and AVC[ J]. IE.EE Trans on Power Systems, 1992,7(3) :447-452. 被引量:1
  • 4Ilic'-Spong M, Christensen J, Eichom K L. Secondary voltage Control Using Pilot Point Information. IEEE Trans on Power Systems, Vol. 3, 1988, (2) :660-668. 被引量:1
  • 5Lagonotte P, et al. Structural Analysis of the Electrical System: Application to Secondary Voltage Control in France[J].IEEE Trans on Power Systems, 1989,4, (2) :479-486. 被引量:1
  • 6PAUL J P, LEOST J Y, TESSERON J M. Survey of the Secondary Voltage Control in France: Present Realization and Investigations. IEEE Trans on Power Systems, 1987, 2 (2):505-511. 被引量:1
  • 7ARCIDIACONO V, CORSI S, NATALE A et al. New Developments in the Applications of ENEL Transmission System Automatic Voltage and Reactive Control. Paris:CIGRE, Report 38/39-06, 1990. 被引量:1
  • 8PIRET J P, ANTOINE J P, STUBBE M et al. The Study of a Centralized Voltage Control Method Applicable to the Belgian System. Paris: CIGRE, Report 39-201, 1992. 被引量:1
  • 9SANCHA J L, FERNANDEZ J L, CORTES A et al. Secondary Voltage Control: Analysis, Solutions and Simulation Results for the Spanish Transmission System. IEEE Trans on Power Systems, 1996, 11(2): 630-638. 被引量:1
  • 10LAGONOTTE P, SABONNADIERE J C, LEOST J C et al.Structural Analysis of the Electrical System: Application to Secondary Voltage Control in France. IEEE Trans on Power Systems, 1989, 4(2): 479--486. 被引量:1

共引文献127

同被引文献57

引证文献4

二级引证文献33

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈