期刊文献+

660MW前后墙对冲燃烧锅炉结焦原因分析与治理 预览

Analysis on reasons of slagging of600 MW front and back-walls opposed firing boiler and treatment
在线阅读 下载PDF
收藏 分享 导出
摘要 针对某厂两台采用前后墙对冲燃烧方式锅炉机组临检后出现的结焦严重问题,对结焦的原因进行分析并采取了严格管控入炉煤质、调整运行参数及燃烧方式等措施,结焦现象明显好转。 In the two front and back-walls opposed firing boilers of a power pant,serious slagging problem was occurred after unplanned overhaul. Aiming at this problem,the reasons of slagging were analyzed. Some measures,such as to cntrol the quality of as fired coal and to adjust the operation parameters and combustion mode,were adopted,and the slsgging phenmenon was obviously improved.
作者 陈飞 CHEN Fei;Datang Huaibei Power Plant;
机构地区 大唐淮北发电厂
出处 《华电技术》 2015年第4期62-63,75共3页 Water Conservancy & Electric Power Machinery
关键词 前后墙对冲燃烧锅炉 结焦 煤质 煤粉细度 空气动力场 front and back-walls opposed firing boiler slagging coal quality fineness of pulverized coal air dynamic field
作者简介 陈飞(1989-),男,江苏徐州人,助理工程师,从事火电厂集控运行工作(E-mail:chenfeihd@163.com)。