期刊文献+

循环流化床锅炉密相区温度测点优化改造 预览

Optimization Reconstruction of Temperature Points on Dense Phase Region of CFB Measurement Boiler
在线阅读 下载PDF
分享 导出
摘要 针对循环流化床锅炉密相区DCS温度显示不均匀、不准确问题,通过数值模拟,分析了锅炉密相区凸台部位的流场分布状况;根据分析结果,对密相区温度测点进行了优化改造。测点改造后,锅炉密相区DCS温度显示较为均匀,显示值能够真实反映炉内实际运行状态,同时验证了数值模拟结果的正确性。 In view of DCS temperature display of the dense phase and accurate on the circulating fluidized bed boiler, through the zone was not evenly numerical simulation, analyzed the boiler dense area protruding part of the flow field distribution. According to the results of the analysis, carry out the optimization and transformation to dense phase zone temperature measuring points. After the transformation, the DCS temperature of the dense phase of the boiler was displayed evenly, the display value could reflect the actual running state of the furnace, and the correctness of the numerical simulation results was verified.
作者 张世鑫 景晓鹏 程海峰 罗英强 李万胜 ZHANG Shixin, JING Xiaopeng, CHENG Haifeng, LUO Yingqiang, LI Wansheng (1.China Huaneng Group Clean Energy Research Institute Co.,Ltd., Beijing 102209, China; 2.Qinghai Salt Lake Industry Co.,Ltd., Golmu 816000, China)
出处 《内蒙古电力技术》 2015年第3期56-58,80共4页 Inner Mongolia Electric Power
关键词 循环流化床锅炉 密相区 数值模拟 欧拉双流体模型 温度测点 CFB boiler dense phase zone numerical simulation Eulerian double fluidmodel temperature measuring point
作者简介 张世鑫(1983),男,河南人,学士,工程师,从事循环流化床锅炉及清洁煤发电技术的研究与应用工作。