旋流对冲锅炉火检信号剧烈波动的原因分析及调整措施 预览 被引量:3

The reason analysis on drastic fluctuation of flame detecting signals in swirl-opposed boiler and its adjustment measures
在线阅读 下载PDF
收藏 分享 导出
摘要 四川广安发电有限责任公司#62锅炉在低负荷状态下投运 D 层燃烧器时炉内火焰检测信号剧烈波动,分析原因为 D 层燃烧器煤粉着火延迟,导致火焰黑龙区过长,未点燃的煤粉影响邻层燃烧。通过调整一次风温度、煤粉细度及一次风、二次风流量等参数,改善了煤粉的着火条件,缩短了煤粉的着火时间,使煤粉进入炉膛后能够快速点燃。燃烧调整后,该锅炉在低负荷状态下投运 D 层燃烧器,炉内火焰检测信号波动情况大为改善。 Through analyzing the drastic fluctuation of flame detecting signals in layer D burner for No. 62 boiler that is working under low load conditions in Sichuan Guang'an power plant,the reason is considered as the pulverized coal of layer D burner ignition delayed and generated an overlength unburned zone,and consequently influenced the combustion of neighbor layer.Through adjusting the parameters,such as temperature of primary air,fineness of pulverized coal,flow of primary air and secondary air et al.,the ignition condition of pulverized coal is improved and the ignition time is shortened,which makes the pulverized coal burnt quickly after entering furnace. After the combustion adjustments,the fluctuation of flame detecting signals becomes normal at low load conditions.
作者 周文台 ZHOU Wentai;Shanghai Power Equipment Research Institute;
出处 《华电技术》 2015年第7期52-54,共3页 Water Conservancy & Electric Power Machinery
关键词 火检波动 燃烧调整 煤粉细度 一次风温度 旋流对冲锅炉 fluctuation of flame detecting signals combustion adjustment fineness of pulverized coal temperature of the primary air swirl-opposed boiler
作者简介 周文台(1981-),男,四川达州人,工程师,工学硕士,从事大型电站锅炉的燃烧调整及能耗检测评估方面的研究(E—mail:zhouwentai@speri.com.cn)。
  • 相关文献

参考文献4

二级参考文献8

共引文献11

同被引文献17

引证文献3

二级引证文献3

投稿分析

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部 意见反馈