期刊文献+

2种电除尘优化改造方案模拟及经济性分析 被引量:1

Simulation and economic analysis of electrostatic dust collector optimization reformation
分享 导出
摘要 中国环境保护部和国家质量监督检验检疫总局联合发布了GB 13223-2014,要求火电厂烟尘排放限值应小于30mg·m^-3,老式单一的电除尘器已经很难达到环保要求。以某电厂为例,对电除尘器入口处接低低温省煤器和将原静电除尘器改造为电袋复合除尘器的2种优化改造方案进行了模拟,并对2种方案的经济性进行了分析,所得结论可供类似机组在电除尘器改造和设计时参考。 Recently,China's Ministry of Environmental Protection and the State Administration for Quality Supervision,Inspection,and Quarantine( GB 13223-2014) jointly set and released standard requirements for flue dust emission limits. As these stipulate a value less than 30 mg·m-(- 3),it has been very difficult for old,single electrostatic dust collectors to meet the new requirements. Taking a power plant as an example,simulations are performed investigating two optimization schemes for installing a low-temperature coal dust collector at the entrance of an electric dust collector and transforming it to use electrostatic-bag precipitation. The resulting conclusions can be used for reference in the design of similar units.
作者 吕太 张雄 杨博然 LYU Tai , ZHANG Xiong, YANG Boran (School of Energy and Power Engineering, Northeast Dianli Univercity,Jilin 132012,China)
出处 《环境工程学报》 CAS CSCD 北大核心 2017年第3期1729-1736,共8页 Techniques and Equipment for Environmental Pollution Control
关键词 低低温省煤器 电袋复合除尘器 模拟计算 经济性分析 LLT-ESP electrostatic-bag precipitation simulate calculate economic analysis
作者简介 第一作者:吕太(1957-),男,硕士,教授,研究方向:电站辅机的优化设计。E-mail:1047601987@qq.com通信作者