期刊文献+
共找到337篇文章
< 1 2 17 >
每页显示 20 50 100
CT图像噪声与辐射剂量及对比剂浓度的相关性研究
1
作者 吕蓉 韩宇欣 +2 位作者 李娜 孙诚 于长路 《临床放射学杂志》 CSCD 北大核心 2019年第6期1128-1131,共4页
目的探讨CT图像噪声与辐射剂量及对比剂浓度的相关性。方法配制浓度为0.5~50.0 mg/ml,间隔0.5 mg/ml的100份对比剂样本,在15种不同扫描条件下扫描,测量并记录CT图像噪声、辐射剂量,分析其是否与扫描条件有关,以及CT图像噪声与辐射剂量... 目的探讨CT图像噪声与辐射剂量及对比剂浓度的相关性。方法配制浓度为0.5~50.0 mg/ml,间隔0.5 mg/ml的100份对比剂样本,在15种不同扫描条件下扫描,测量并记录CT图像噪声、辐射剂量,分析其是否与扫描条件有关,以及CT图像噪声与辐射剂量及对比剂浓度的关系。不同扫描条件下CT图像噪声是否有差异采用方差分析,辐射剂量与扫描条件的关系采用Pearson相关分析,CT图像噪声与辐射剂量及对比剂浓度的关系采用Pearson相关分析并计算其回归方程,根据方程建模计算CT图像噪声及辐射剂量同时为最低的节点。结果不同扫描条件下,CT图像噪声差异均具有统计学意义(P<0.05)。辐射剂量与管电压及管电流均有相关性(r=0.996~1.000,P<0.05)。CT图像噪声与辐射剂量的相关方程分别为100 m A:N100mA=-37.565Ln(D100mA)+164.893,R2=0.905,P=0.013;200 m A:N200mA=-32.711Ln(D200mA)+167.456,R2=0.935,P=0.007;280 m A:N280mA=-29.549Ln(D280mA)+158.628,R2=0.925,P=0.009。其两者同时最小的节点分别为100 m A:N100mA=31.81,D100mA=34.56 m Gy·cm;200 m A:N200mA=47.33,D200mA=39.34 m Gy·cm;280 m A:N280mA=50.62,D280mA=38.68 m Gy·cm(D为辐射剂量,N为图像噪声,R2为决定系数)。CT图像噪声与对比剂浓度有一定的相关性(r=0.512~0.777)。结论 CT图像噪声与辐射剂量和对比剂浓度有一定相关性,实际工作中要意识到这一点,并利用其达到保证图像质量的前提下,减少辐射剂量的目的。 展开更多
关键词 管电压 管电流 CT图像噪声 辐射剂量 对比剂浓度
联影16排CT高压故障解析 预览
2
作者 陈卫东 李仁阳 张博 《中国医疗设备》 2019年第4期180-184,共5页
目的通过分析联影16排CT的高压故障,探讨维修方法,积累维修经验,能够更加准确的进行维修定位。方法研究联影16排CT的高压球管的工作原理和相互关系,分析KV上电对阴极和栅极的影响,从而对故障现象定位。结果通过本次维修,解决了设备故障... 目的通过分析联影16排CT的高压故障,探讨维修方法,积累维修经验,能够更加准确的进行维修定位。方法研究联影16排CT的高压球管的工作原理和相互关系,分析KV上电对阴极和栅极的影响,从而对故障现象定位。结果通过本次维修,解决了设备故障,同时也对高压设备有了更加深入仔细的了解,对以后的维修有很大帮助。结论本篇文章着重讲解了高压和球管之间的关系,它们相互影响。在判断故障上,我们要理清思路根据其原理逐步排查、谨慎求证,最终确定故障点完成维修。 展开更多
关键词 球管 高压 高压倍增器 栅极控制错误 阴极过流
在线阅读 下载PDF
双源CT70与120kV不同CARE Dose 4D预设值下图像质量的对比研究 预览
3
作者 赵海波 罗焕江 +2 位作者 廖明壮 龙腾河 冯庆 《医疗卫生装备》 CAS 2019年第2期56-59,共4页
目的:探讨双源CT不同管电压和CARE Dose 4D预设值下的辐射剂量与图像质量相关性,为低剂量扫描方案奠定基础。方法:使用西门子FLASH双源CT对水模进行图像采集。根据管电压分为A、B 2组,A组:管电压70 kV,B组:管电压120 kV。每组CARE Dose... 目的:探讨双源CT不同管电压和CARE Dose 4D预设值下的辐射剂量与图像质量相关性,为低剂量扫描方案奠定基础。方法:使用西门子FLASH双源CT对水模进行图像采集。根据管电压分为A、B 2组,A组:管电压70 kV,B组:管电压120 kV。每组CARE Dose 4D预设值均为150、200、250、300、350和400 mAs,其他参数不变。采用SPSS 18.0软件对CT值、图像信噪比(signal noise ratio,SNR)、剂量长度乘积(dose length produce,DLP)、容积CT剂量指数(CT dose index volumes,CTDIvol)进行统计分析,以P<0.05为差异有统计学意义。结果:在A组中,不同预设值间CT值无统计学差异(F=0.832,P=0.537 >0.05),CT值标准差具有统计学差异(F=6.115,P=0.001<0.05);在B组中,不同预设值间CT值无统计学差异(F=0.880,P=0.506 >0.05),CT值标准差具有统计学差异(F=9.470,P=0.000<0.05)。在相同预设值150 mAs下,A组和B组间CT值和SNR值无统计学差异(P >0.05),B组的CTDIvol和DLP是A组的4.4倍。结论:在相同的管电压下,随着CARE Dose 4D预设值增加,辐射剂量增大,噪声降低,图像质量提高;在相同的CARE Dose 4D预设值下,70 kV下降低了辐射剂量,但与120 kV下图像质量没有统计学差异。 展开更多
关键词 双源CT CARE DOSE 4D预设值 管电压 毫安秒 辐射剂量 图像质量
在线阅读 下载PDF
低电压、低碘对比剂剂量应用于头颈CTA患者的临床研究 预览
4
作者 王良东 《中国CT和MRI杂志》 2019年第4期23-25,78共4页
目的探究低电压、低碘对比剂剂量在头颈CT血管造影(CTA)中的临床应用。方法按照随机数字表法将80例行头颈CTA的患者分为常规组及双低组,每组40例,常规组患者CTA对比剂剂量为60mL,管电压为120kVp,双低组患者CTA对比剂剂量为0.3ml/kg,管... 目的探究低电压、低碘对比剂剂量在头颈CT血管造影(CTA)中的临床应用。方法按照随机数字表法将80例行头颈CTA的患者分为常规组及双低组,每组40例,常规组患者CTA对比剂剂量为60mL,管电压为120kVp,双低组患者CTA对比剂剂量为0.3ml/kg,管电压为100kVp。记录两组受试者使用对比剂剂量、剂量长度乘积(DLP),计算体型特异性剂量估计值(SSDE),对两组图像进行客观及主观评价。结果双低组受试者对比剂剂量、DLP、SSDE均显著低于常规组(P<0.05);双低组在左、右大脑中动脉中的图片客观质量评分显著低于常规组(P<0.05);其他兴趣区图片质量评分组间比较差异无统计学意义(P>0.05);两组受试者CTA图像质量主观评价及合格率差异均无统计学意义(P>0.05)。结论低电压、低碘对比剂剂量可显著降低头颈部CTA扫描辐射剂量及对比剂碘的用量,图像质量可满足临床疾病诊断。 展开更多
关键词 头颈CT血管造影 碘对比剂 管电压 辐射量 图像质量
在线阅读 免费下载
低剂量扫描方案在头颈CT血管成像小剂量团注测试中的优化
5
作者 曾禹莉 王贵良 +3 位作者 王琪 马荣 邓明坤 唐蓓 《实用放射学杂志》 CAS 北大核心 2019年第1期114-117,129共5页
目的 探讨低剂量扫描方案在64排头颈CTA小剂量团注测试(Test-Bolus)技术中的优化。方法 将120例患者Test-Bolus期随机分3组扫描:常规组(A组:120 kV,100 mA)、低剂量组(B1组:100 kV,50 mA;B2组:100 kV,100 mA)扫描,每组40例。主观(主观评... 目的 探讨低剂量扫描方案在64排头颈CTA小剂量团注测试(Test-Bolus)技术中的优化。方法 将120例患者Test-Bolus期随机分3组扫描:常规组(A组:120 kV,100 mA)、低剂量组(B1组:100 kV,50 mA;B2组:100 kV,100 mA)扫描,每组40例。主观(主观评分)、客观(测量主动脉弓CT值)评价3组图像质量,并比较、分析图像质量及辐射剂量。 结果 ①3组图像质量均满足诊断要求,主观评分比较,差异无统计学意义(P>0.05);②A、B1、B2 3组,B1组与A组,B2组与A组间CT值比较,差异有统计学意义(P<0.05),B1与B2组间CT值差异无统计学意义(P>0.05);③3组容积CT剂量指数(CTDIvol)和剂量长度乘积(DLP)比较,差异有统计学意义(P<0.05),B1、B2组CTDIvol、DLP较A组降低了70%、38%。 结论 在64排头颈CTA Test-Bolus技术中,采用100 kV、50 mA低剂量方案既能保证图像质量,又能使辐射剂量较常规扫描降低70%。 展开更多
关键词 计算机体层成像 血管造影术 小剂量团注测试 管电压 辐射剂量
基于X射线法无损测定再造烟叶基片的定量 预览
6
作者 朱宏福 堵劲松 +4 位作者 常纪恒 樊新顺 田晓辉 王嘉绍 鲁端峰 《食品与机械》 北大核心 2019年第2期97-102,共6页
采用X射线定量仪对不同配比的再造烟叶基片进行测定,通过分析管电压对该仪器测定结果的重复性、灵敏度和检出限的影响,优化出6 000V的管电压较适合测定基片的定量;并且发现测定不同配比再造烟叶基片的定量指示值和定量实测值有较高的线... 采用X射线定量仪对不同配比的再造烟叶基片进行测定,通过分析管电压对该仪器测定结果的重复性、灵敏度和检出限的影响,优化出6 000V的管电压较适合测定基片的定量;并且发现测定不同配比再造烟叶基片的定量指示值和定量实测值有较高的线性关系,建立的线性回归模型决定系数>0.99,预测最大相对偏差<1%;含有不同含量碳酸钙的再造烟叶基片对模型的建立影响较大,含有不同含量梗末比和外加纤维的再造烟叶基片对模型的建立影响相对较小。 展开更多
关键词 X射线法 再造烟叶基片 管电压 定量
在线阅读 免费下载
锂离子电池供电型便携式高频X射线机的研制 预览
7
作者 曾莹莹 陈海辉 +1 位作者 肖化武 易荣喜 《井冈山大学学报:自然科学版》 2018年第3期52-57,共6页
在总结相关专利的基础上,本文发明了一种便携式高频X射线机的锂离子电池的供电方法和控制电路。阐述了锂离子电池给X射线管的高压供电和灯丝加热。设计了半桥逆变的主电路方案,以及X射线机的管电压和管电流的反馈检测电路装置。样机总质... 在总结相关专利的基础上,本文发明了一种便携式高频X射线机的锂离子电池的供电方法和控制电路。阐述了锂离子电池给X射线管的高压供电和灯丝加热。设计了半桥逆变的主电路方案,以及X射线机的管电压和管电流的反馈检测电路装置。样机总质量1.5 kg,总体积不大于15 cm×15 cm×15 cm。电池组容量可曝光300次,输出电压范围在19~25 V之间,管电压60 k V,波动5%,管电流2 m A,波动8%。样机轻便,体积小,便于携带,且能拍摄出清晰图片,能满足拍片要求。基于半桥逆变的供电方案,其管电流、管电压的波动比全桥逆变供电时要大,即精度会有所降低,但其结构简单,成本降低,体积减少,适合制作小容量的便携式X射线机。 展开更多
关键词 锂离子电池组 便携式 高频X射线机 管电压 管电流
在线阅读 下载PDF
不同球管参数设定对肺磨玻璃结节CT筛查的影响-体模研究
8
作者 孙英丽 金倞 +5 位作者 高盼 李骋 沈云 滑炎卿 张国桢 李铭 《临床放射学杂志》 CSCD 北大核心 2018年第7期1215-1220,共6页
目的分析不同CT球管参数(kV,mA)的设定对于肺部不同大小磨玻璃结节检出的影响,探讨合适的肺部低剂量CT筛查的扫描参数。方法将直径为5 mm、8 mm、10 mm、12 mm,CT值为-630 HU和-800 HU,共8个球形小结节随机置于仿真胸部体模内,分别在L... 目的分析不同CT球管参数(kV,mA)的设定对于肺部不同大小磨玻璃结节检出的影响,探讨合适的肺部低剂量CT筛查的扫描参数。方法将直径为5 mm、8 mm、10 mm、12 mm,CT值为-630 HU和-800 HU,共8个球形小结节随机置于仿真胸部体模内,分别在Lightspeed VCT和Discovery HD750上,设定不同管电压和管电流对体模进行扫描。由两名高年资胸部放射诊断医师分别对小结节的可发现、可诊断和整体图像质量进行主观评价。采用Kappa分析评价两名观察者评定结果的一致性。结果两名医师对小结节的可发现、可诊断分析及各组图像整体质量的评价具有较好的一致性。对于CT值为-630 HU的5 mm微小磨玻璃结节:HDCT上,140 kV,20mA;120 kV,20 mA;100 kV,20 mA;80 kV,40 mA可满足小结节的筛查要求;140 kV,20 mA;120 kV,40 mA;100 kV,80 mA;80 kV,80 mA可满足小结节诊断要求。VCT上,140 kV,20 mA;120 kV,20 mA;80 kV,40 mA可满足小结节的筛查要求;140 kV,40 mA;120 kV,80 mA;80 kV,120 mA可满足小结节的诊断要求。对于CT值为-800 HU的5mm微小磨玻璃结节:HDCT上,140 kV,20 mA;120 kV,20 mA;100 kV,40 mA;80 kV,120 mA可满足小结节筛查的要求;140 kV,40 mA;120 kV,80 mA;100 kV,20 mA;80 kV,200 mA可满足小结节的诊断要求。在VCT上,140 kV,40 mA;120 kV,80 mA;80 kV,280 mA可满足小结节筛查发现的要求;140 kV,120 mA;120 kV,200 mA可满足小结节的诊断要求。管电压为80 kV时,所有条件的管电流都不能满足小结节的诊断要求。结论在本体模研究中,对于CT值为-630 HU的5 mm微小磨玻璃结节,采用100 kV,20 mA(HDCT);80 kV,40 mA(VCT)的扫描条件可以满足小结节筛查的要求,对于其细节的观察(诊断时),需采用80 kV,80 mA(HDCT);80 kV,120 mA(VCT)的扫描条件进行检查;对于CT值为-800 HU的5 mm微小磨玻璃结节,筛查可以采用120 kV,20 mA(HDCT);140 kV,40 mA(VCT)的扫描条件,诊断可以采用140 kV,40 mA(HDCT);140 kV,120 mA(VCT)的� 展开更多
关键词 磨玻璃结节 CT低剂量筛查 体模 管电流 管电压
管电压对胸部CT图像质量及辐射剂量的影响 预览 被引量:1
9
作者 袁颖 卢东生 钟朝辉 《中国医疗设备》 2018年第2期69-72,共4页
目的本文探讨了应用自动管电流调节技术(AutomaticTubeMedicalUniversity,ATCM)行胸部CT扫描时,管电压的变化对图像质量及辐射剂量的影响。方法应用GEOptimaCT680CT机采用ATCM技术对胸部仿真模体行CT扫描。共进行3纽扫描,其中A组... 目的本文探讨了应用自动管电流调节技术(AutomaticTubeMedicalUniversity,ATCM)行胸部CT扫描时,管电压的变化对图像质量及辐射剂量的影响。方法应用GEOptimaCT680CT机采用ATCM技术对胸部仿真模体行CT扫描。共进行3纽扫描,其中A组管电压为80kVp,B组管电压为100kVp,C纽管电压为120kVp,各组分别预设5个噪声指数(NoiseIndex,NI)级别(10、15、20、25和30)扫描体模。记录每组图像的容积CT剂量指数(VolumetricCTDoseIndex,CTDI。1)和剂量长度乘积(Dose—LengthProduct,DLP)。测量并比较图像的客观噪声(StandardDeviation,SD),由两名有经验的放射科医生采用双盲法对磨玻璃密度结节(GroundGlassNodules,GGN)进行主观评分。结果研究结果显示,除NI为10以外,在其他相同NI时,图像客观噪声无统计学差异。NI在15、20、25和30时,A组与c组比较时,DLP分别增加21.96,16.25、9.18~m6.37mGy·cm。B组与C组比较时,DLP分别增加14.05、8.50、5.17和3.65mGy·cm。相同预设NI时不同管电压下对GGN主观评分无明显统计学差异,且两名观察者间的一致性中等或良好。结论应用ATCM技术,相同预设NI下管电压的变化对图像质量不会产生明显影响。患者的辐射剂量随着扫描管电压的增高而降低。 展开更多
关键词 自动管电流调制技术 管电压 辐射剂量 图像质量 体层摄影术
在线阅读 下载PDF
Low-radiation and high image quality coronary computed tomography angiography in“real-world”unselected patients 预览
10
作者 Caryl Elizabeth Richards Stephen Dorman +8 位作者 Patricia John Anthony Davies Sharon Evans Tishi Ninan David Martin Sriranj Kannoly Gail Roberts-Davies Mark Ramsey Daniel Rhys Obaid 《世界放射学杂志:英文版(电子版)》 2018年第10期135-142,共8页
AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected“real world”patients.METHODS In this single-centre st... AIM To determine the radiation dose and image quality in coronary computed tomography angiography(CCTA)using state-of-the-art dose reduction methods in unselected“real world”patients.METHODS In this single-centre study,consecutive patients in sinus rhythm underwent CCTA for suspected coronary artery disease(CAD)using a 320-row detector CT scanner.All patients underwent the standard CT acquisition protocol at our institute(Morriston Hospital)a combination of dose saving advances including prospective electrocardiogram-gating,automated tube current modulation,tube voltage reduction,heart rate reduction,and the most recent novel adaptive iterative dose reconstruction 3D(AIDR3D)algorithm.The cohort comprised real-world patients for routine CCTA who were not selected on age,body mass index,or heart rate.Subjective image quality was graded on a 4-point scale(4=excellent,1=non-diagnostic).RESULTS A total of 543 patients were included in the study with a mean body weight of 81±18 kg and a pre-scan mean heart rate of 70±11 beats per minute(bpm).When indicated,patients received rate-limiting medication with an oral beta-blocker followed by additional intravenous beta-blocker to achieve a heart rate below 65 bpm.The median effective radiation dose was 0.88 mSv(IQR,0.6-1.4 mSv)derived from a Dose Length Product of 61.45 mGy.cm(IQR,42.86-100.00 mGy.cm).This also includes what we believe to be the lowest ever-reported radiation dose for a routine clinical CCTA(0.18 mSv).The mean image quality(±SD)was 3.65±0.61,with a subjective image quality score of 3(“good”)or above for 93%of patient CCTAs.CONCLUSION Combining a low-dose scan protocol and AIDR3D with a 320-detector row CT scanner can provide high quality images at exceptionally low radiation dose in unselected patients being investigated for CAD. 展开更多
关键词 Effective RADIATION dose TUBE voltage TUBE current Iterative reconstruction Coronary computed tomography ANGIOGRAPHY Image quality Prospectively ELECTROCARDIOGRAM GATING
在线阅读 免费下载
腹部水模不同管电压、管电流CT扫描的研究 预览 被引量:1
11
作者 杨炎炎 黄仲奎 《医学影像学杂志》 2018年第4期678-682,共5页
目的 通过不同的管电压、管电流(mAs)对水模反复扫描,探索最适腹部低剂量图像的扫描条件。方法 将碘剂、生理盐水按比例配制成实验水模,固定于CT质量确认模上,置于扫描床中心。选择人体腹部扫描条件,固定扫描条件(层厚、螺距、FOV等)不... 目的 通过不同的管电压、管电流(mAs)对水模反复扫描,探索最适腹部低剂量图像的扫描条件。方法 将碘剂、生理盐水按比例配制成实验水模,固定于CT质量确认模上,置于扫描床中心。选择人体腹部扫描条件,固定扫描条件(层厚、螺距、FOV等)不变,仅改变mAs或管电压,对配有不同碘浓度的七只试管进行扫描,测量CT图像的一定感兴趣区(ROI)的CT值(±SD,SD表示噪声值),计算得出SNR,并将常规扫描得到的CT值、图像噪声、SNR与改变扫描条件后的进行比较。观察不同管电压、管电流对CT值、图像噪声值及SNR的影响。结果 1)管电压为120kV时,管电流降到60mAs时,图像质量明显下降,达不到临床诊断标准;管电压为100kV,管电流降到120mAs时,图像质量明显下降,达不到临床诊断标准;管电压为80kV,管电流为200mAs或低于200mAs时,图像质量达不到临床诊断标准;管电压为70kV,管电流为200mAs或低于200mAs时,图像质量达不到临床诊断标准;2)CT值、SNR值均随对比剂碘浓度的升高而升高;CT值随电压升高而降低,而电压为100kV时,SNR值最大。结论 腹部低剂量检查时,推荐扫描条件100kV,150mAs,既能降低辐射剂量,也能得到接近管电压120kV、200mAs图像质量的图像。 展开更多
关键词 管电压 管电流 图像质量 体层摄影术 X线计算机
在线阅读 下载PDF
便携式X荧光仪检出限影响因素的研究
12
作者 杜海燕 赖万昌 +3 位作者 石希瑜 陈诚 胡燕 赵瑞 《核技术》 CSCD 北大核心 2018年第1期13-19,共7页
讨论了便携式能量色散型X荧光仪检出限受背景扣除方法、管电压与管电流的影响。采用空白样扣本底法、线性本底扣除法、斯托林斯基法(Sterlinski)三种方法扣本底,试验了与之适宜的管电压与管电流范围,比较了三种方法的优缺点。检出... 讨论了便携式能量色散型X荧光仪检出限受背景扣除方法、管电压与管电流的影响。采用空白样扣本底法、线性本底扣除法、斯托林斯基法(Sterlinski)三种方法扣本底,试验了与之适宜的管电压与管电流范围,比较了三种方法的优缺点。检出限与测定限存在一定的对应关系,利用检出限得到测定限,对低含量的样品进行了定量的分析。为降低检出限值和更准确地测量低含量金属元素在背景扣除方法、测量条件等方面的选择提供参考。 展开更多
关键词 X荧光仪 检出限 本底扣除 管电压 管电流
128MSCT应用三低技术结合iDose^4在肺动脉成像的研究 预览
13
作者 曹治婷 陈刚 +4 位作者 刘铁军 廖玉荣 廖明星 梁丽华 曹治柳 《医学影像学杂志》 2018年第12期2030-2034,共5页
目的探讨128MSCT应用三低技术结合iDose^4在肺动脉成像的可行性。方法对体质量指数正常疑似肺动脉栓塞60例患者行CT肺动脉血管成像(CTPA)检查,随机分两组,各30例,其中常规剂量组(A组)采用120kV、200mAs,370mgI/ml对比剂60ml,重建图像采... 目的探讨128MSCT应用三低技术结合iDose^4在肺动脉成像的可行性。方法对体质量指数正常疑似肺动脉栓塞60例患者行CT肺动脉血管成像(CTPA)检查,随机分两组,各30例,其中常规剂量组(A组)采用120kV、200mAs,370mgI/ml对比剂60ml,重建图像采用滤波反投影(FBP)技术;实验组(B组)采用80kVp、80mAs,300mgI/ml对比剂35ml,重建图像分别采用iDose^4(B1组)及FBP技术(B2组);记录各组的CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效剂量(ED)、背景噪声(BN)、肺动脉强化CT平均值(SIvessel)、肺动脉噪声比(SNR)和对比信噪比(CNR)。各组结果采用ANOVA单因素方差分析,组内两两比较采用LSD法,主观图像质量评分比较采用秩和检验。结果A及B1组图像均满足诊断要求,且两组图像噪声、SNR、CNR、图像总体质量比较差异,无统计学意义(P>0.05)。B组较A组的ED值、对比剂总碘量分别下降了76.2%及52.7%。结论128MSCT应用三低技术结合iDose^4行肺动脉CTPA检查是可行和有效的,同时降低了患者的辐射剂量及对比剂量的碘摄入量,具有较高的临床应用价值。 展开更多
关键词 肺动脉血管成像 体层摄影术 X线计算机 管电压 辐射剂量 迭代重建
在线阅读 下载PDF
西门子CT模拟机图像均匀性的长期稳定性分析 预览
14
作者 时飞跃 柏正璐 +2 位作者 秦航 秦伟 林强 《中国医学物理学杂志》 CSCD 2018年第9期1035-1038,共4页
目的:分析使用水模体进行日常质量检测的数据,评价西门子Sensation Open CT模拟机图像均匀性的长期稳定性。方法:使用水模体,调用日常质量检测程序Daily Quality Check,每月检测西门子Sensation OpenCT模拟机,得到标称管电压120kV... 目的:分析使用水模体进行日常质量检测的数据,评价西门子Sensation Open CT模拟机图像均匀性的长期稳定性。方法:使用水模体,调用日常质量检测程序Daily Quality Check,每月检测西门子Sensation OpenCT模拟机,得到标称管电压120kV和140kV两种情形的CT图像,通过手动勾画和计算得到图像均匀性的数据。对2017年3月~2018年2月的CT图像均匀性数据进行统计学分析和比较研究。结果:在120kV情形下,第1至第6层(层厚4.8mm)图像均匀性值分别为:(2.5±0.4)、(2.8±0.6)、(2.2±0.2)、(1.5±0.7)、(1.4±0.4)和(1.0±0.3)HU;在140kV情形下,第1至第6层图像均匀性值分别为:(2.0±0.2)、(3.0±0.4)、(1.5±0.5)、(0.7±0.4)、(0.5±0.2)和(0.7±0.5)HU。该CT模拟机的图像均匀性在这12个月内的变化很小,所有值均在0~4HU内。结论:在12个月内,该西门子CT模拟机图像均匀性比较稳定,满足使用要求。层面位置是影响图像均匀性的因素之一。 展开更多
关键词 CT模拟机 图像均匀性 管电压 长期稳定性
在线阅读 免费下载
低管电压和低剂量对比剂行256排螺旋CT肺动脉成像的可行性分析
15
作者 姚仲欣 解宝泉 张静华 《中国煤炭工业医学杂志》 2018年第6期596-599,共4页
目的探讨低管电压和低剂量对比剂行256排螺旋CT肺动脉成像的可行性。方法收集2018年3月-2018年8月来该院就诊的肺动脉栓塞患者,共64例。通过随机数字表法将患者分成二组。观察组32例,使用管电压100kV、造影对比剂碘帕醇370mg/ml,剂量40... 目的探讨低管电压和低剂量对比剂行256排螺旋CT肺动脉成像的可行性。方法收集2018年3月-2018年8月来该院就诊的肺动脉栓塞患者,共64例。通过随机数字表法将患者分成二组。观察组32例,使用管电压100kV、造影对比剂碘帕醇370mg/ml,剂量40ml;对照组32例,使用管电压120kV、造影对比剂碘帕醇370mg/ml,剂量70ml。观察指标包括质量评估得分、背景噪声(BN)、信号噪声比(SNR)、对比度噪声比(CNR)、CT剂量指数(CTDIvol),计算剂量长度积(DLP),比较二组观察指标。结果观察组与对照组主观图像质量评估比较,差异无统计学意义(P>0.05)。观察组与对照组客观的图像量化指标比较,差异无统计学意义(P>0.05)。剂量辐射指标CTDIvol、DLP二组比较,差异有统计学意义(P<0.05)。结论低管电压、低剂量对比剂能够保证肺动脉图像成像质量、降低辐射剂量,具有一定的可行性,值得推广。 展开更多
关键词 体层摄影术 管电压 256排螺旋CT 肺动脉成像 辐射剂量
直流电磁继电器反向电压抑制方法浅析 预览
16
作者 龙先江 《煤矿机电》 2018年第6期42-44,共3页
以继电器驱动电路为基础,分析在该电路中并联续流二极管、并联齐纳二极管、并联TVS管三种方式来抑制反向电压,将反向电压限制在安全范围内,保护前级驱动电路,减小尖峰电压所产生的干扰,同时提供电感储能释放通道,削弱接点放电火花。结... 以继电器驱动电路为基础,分析在该电路中并联续流二极管、并联齐纳二极管、并联TVS管三种方式来抑制反向电压,将反向电压限制在安全范围内,保护前级驱动电路,减小尖峰电压所产生的干扰,同时提供电感储能释放通道,削弱接点放电火花。结合试验数据和仿真波形,给出该三种电压抑制方法的适用环境。 展开更多
关键词 继电器驱动 TVS管 续流二极管 齐纳二极管 反向电压
在线阅读 下载PDF
压接管“画印”与欠压、过压缺陷的关系研究 预览
17
作者 赵永强 孟广伟 黄振鹏 《黑龙江科学》 2018年第20期96-97,共2页
随着特高压技术的逐步完善及新材料的推广应用,导地线的型号逐步丰富,导地线压接的重性进一步凸显。在输电线路检修过程中普遍发现的压接管欠压、过压现象,严重影响压接管的力学性能,压接过程画印错误直接导致欠压、过压的产生。压接的... 随着特高压技术的逐步完善及新材料的推广应用,导地线的型号逐步丰富,导地线压接的重性进一步凸显。在输电线路检修过程中普遍发现的压接管欠压、过压现象,严重影响压接管的力学性能,压接过程画印错误直接导致欠压、过压的产生。压接的各类标记画印正确性对压接质量造成的影响程度不同,压接操作人员必须采取可靠手段确保画印准确性。 展开更多
关键词 压接管 耐张线夹 画印 欠压 过压
在线阅读 下载PDF
自动管电流模式下管电压对CT辐射剂量和影像质量影响的模体研究
18
作者 刘丹丹 ·崔莹 +2 位作者 赵波 张永县 牛延涛 《中华放射医学与防护杂志》 CSCD 北大核心 2018年第9期710-714,共5页
目的 探讨自动管电流调制模式下行头颈部和胸部CT扫描时,管电压的改变对辐射剂量及影像质量的影响。方法 自动管电流和自动管电压模式下,对头颈部和胸部模体进行常规CT扫描。自动管电流模式下,管电压分别手动选择70、80、100、120和1... 目的 探讨自动管电流调制模式下行头颈部和胸部CT扫描时,管电压的改变对辐射剂量及影像质量的影响。方法 自动管电流和自动管电压模式下,对头颈部和胸部模体进行常规CT扫描。自动管电流模式下,管电压分别手动选择70、80、100、120和140 kV,对头颈部和胸部模体进行常规CT扫描。每种管电压下定位像扫描3次,再进行1次螺旋扫描。头颈部模体在眼眶中心及第5颈椎(C5)椎体上缘层面选取感兴趣区(ROI),胸部模体在肺尖及气管分叉层面选取ROI,测量记录对比噪声比(CNR)。用热释光剂量计(TLD)测量每次扫描时眼晶状体和乳腺的器官剂量(取3次测量的平均值),计算定位像和螺旋扫描的累积值。记录每次扫描的容积CT剂量指数(CTDIvol),并计算CTDIvol累积值。最后通过计算品质因数(FOM),找到最优化的管电压值。结果 自动管电流和自动管电压模式时,头颈部自动选择120 kV和108 mAs,胸部自动选择80 kV和167 mAs。自动管电流模式时,手动选择70 kV时眼晶状体辐射剂量和CTDIvol值最小(分别为0.779和4.070 mGy),140 kV时眼晶状体辐射剂量和CTDIvol值最大(分别为2.571和25.670 mGy)。70 kV时乳腺辐射剂量和CTDIvol值最小(分别为0.698和0.900 mGy),140 kV时乳腺辐射剂量和CTDIvol值最大(分别为3.452和7.400 mGy)。CNR值在眼眶和C5椎体上缘层面分别为51.30-118.36和80.78-173.12,在肺尖和气管分叉层面分别为50.15-129.58和49.63-115.40。FOM因子在眼眶层面80 kV最大,在C5椎体上缘层面120 kV最大,在肺尖和气管分叉层面都是70 kV最大。头颈部模体最佳管电压:眼眶层面手动100 kV,颈部层面自动管电压模式(120 kV)。胸部模体最佳管电压:手动100 kV。结论 管电压的选择对CT扫描的辐射剂量和影像质量影响较大。对于常规CT扫描,手动100 kV适合眼眶区域扫描,自动120 kV适� 展开更多
关键词 体层摄影术 X射线计算机 辐射剂量 管电压
低管电压结合等渗低浓度对比剂CT肺动脉血管成像的护理体会 预览
19
作者 钟庆芳 武惠明 《海南医学》 CAS 2018年第13期1916-1919,共4页
目的探讨低管电压结合等渗低浓度对比剂CT肺动脉成像检查中的护理要点及经验。方法回顾性分析2015年4月至2016年3月在江苏省中医院行CT肺动脉成像检查的42例患者。采用20 mL等渗低浓度对比剂(碘克沙醇270 mg I/mL),80 k V管电压联合... 目的探讨低管电压结合等渗低浓度对比剂CT肺动脉成像检查中的护理要点及经验。方法回顾性分析2015年4月至2016年3月在江苏省中医院行CT肺动脉成像检查的42例患者。采用20 mL等渗低浓度对比剂(碘克沙醇270 mg I/mL),80 k V管电压联合迭代重建技术CT肺动脉成像的患者资料,总结对临床具有指导价值的重点护理方法及经验。结果 42例患者均未出现对比剂渗漏现象,无碘对比剂不良反应的发生,3例经左侧静脉建立通路的患者出现轻度射线硬化束伪影,图像质量均能够满足临床诊断要求。结论检查前安抚患者心理并进行有效的呼吸训练,检查过程中合理选择对比剂的注射方案以及检查后对患者的密切观察是快速、安全、有效完成检查的关键。 展开更多
关键词 护理 管电压 对比剂 肺动脉栓塞 肺动脉成像
在线阅读 免费下载
平板对接焊缝射线检测中管电压对散射比的影响
20
作者 于德军 廖良进 +2 位作者 曾令青 张学锋 刘贵吉 《无损检测》 2018年第5期56-57,63共3页
为了了解平板对接焊缝射线检测中管电压对散射比的影响,并更好地保证底片影像质量,在其他透照参数不变的情况下,通过改变管电压来研究散射比的变化规律。结果表明:在管电流、曝光时间和焦距等参数相同的条件下,随着管电压的增加,散射... 为了了解平板对接焊缝射线检测中管电压对散射比的影响,并更好地保证底片影像质量,在其他透照参数不变的情况下,通过改变管电压来研究散射比的变化规律。结果表明:在管电流、曝光时间和焦距等参数相同的条件下,随着管电压的增加,散射比呈减小的趋势。试验为平板对接焊缝射线检测中管电压的选取提供了参考依据。 展开更多
关键词 射线检测 平板对接焊缝 散射比 管电压
上一页 1 2 17 下一页 到第
使用帮助 返回顶部 意见反馈