BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects (PmVSD) because of serious complications, such as heart block and tricuspid ...BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects (PmVSD) because of serious complications, such as heart block and tricuspid regurgitation (TR), associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable. AIM To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus (PDA) occluder. METHODS We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed. RESULTS All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within 48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed.CONCLUSION Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted.展开更多
Functional tricuspid regurgitation(TR)primarily arises from asymmetric dilation of the tricuspid annulus in the setting of right ventricular dysfunction and enlargement in response to left-sided myocardial and valvula...Functional tricuspid regurgitation(TR)primarily arises from asymmetric dilation of the tricuspid annulus in the setting of right ventricular dysfunction and enlargement in response to left-sided myocardial and valvular abnormalities.Even if the TR is not severe at the time of mitral valve surgery,it can worsen and even appear late after successful mitral valve surgery,which portends a poor prognosis.Despite data demonstrating inferior outcomes in the presence of residual TR,surgical repair for functional TR remains underused.Acceptance of TR,in the presence of tricuspid annular dilation,may be unacceptable.Surgical repair should consist of placement of a rigid or semirigid annular ring,which has been shown to provide superior durability as compared with suture and flexible band techniques.Finally,percutaneous annuloplasty for correction of functional TR may allow treatment of patients with recurrent TR at high risk of reoperation.展开更多
文摘BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects (PmVSD) because of serious complications, such as heart block and tricuspid regurgitation (TR), associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable. AIM To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus (PDA) occluder. METHODS We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed. RESULTS All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within 48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed.CONCLUSION Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted.
文摘Functional tricuspid regurgitation(TR)primarily arises from asymmetric dilation of the tricuspid annulus in the setting of right ventricular dysfunction and enlargement in response to left-sided myocardial and valvular abnormalities.Even if the TR is not severe at the time of mitral valve surgery,it can worsen and even appear late after successful mitral valve surgery,which portends a poor prognosis.Despite data demonstrating inferior outcomes in the presence of residual TR,surgical repair for functional TR remains underused.Acceptance of TR,in the presence of tricuspid annular dilation,may be unacceptable.Surgical repair should consist of placement of a rigid or semirigid annular ring,which has been shown to provide superior durability as compared with suture and flexible band techniques.Finally,percutaneous annuloplasty for correction of functional TR may allow treatment of patients with recurrent TR at high risk of reoperation.