Ascending aortic dilatation rate after transcatheter aortic valve replacement in patients with bicuspid and tricuspid aortic stenosis:A multidetector computed tomography follow-up study 预览
1
作者 Yu-xin He Jia-qi Fan +6 位作者 Qi-feng Zhu Qi-jing Zhou Ju-bo Jiang Li-han Wang Stella Ng Xian-bao Liu Jian-an Wang 《世界急诊医学杂志(英文)》 CAS CSCD 2019年第4期197-204,共8页
BACKGROUND: Current data is lacking about the progression of ascending aortic dilatation after transcatheter aortic valve replacement(TAVR) in aortic stenosis(AS) patients with bicuspid aortic valve(BAV) and tricuspid... BACKGROUND: Current data is lacking about the progression of ascending aortic dilatation after transcatheter aortic valve replacement(TAVR) in aortic stenosis(AS) patients with bicuspid aortic valve(BAV) and tricuspid aortic valve(TAV). This study aims to assess the ascending aortic dilatation rate(mm/year) after TAVR in patients with BAV versus TAV using a multidetector computed tomography(MDCT) fol ow-up and to determine the predictors of ascending aortic dilatation rate.METHODS: Severe AS patients undergoing TAVR from March 2013 to March 2018 at our center with MDCT follow-ups were included. BAV and TAV were identified using baseline MDCT. Baseline and follow-up MDCT images were analyzed,and the diameters of ascending aorta were measured. Study end point is ascending aortic dilatation rate(mm/year). Furthermore,factors predicting ascending aortic dilatation rate were also investigated.RESULTS: Two hundred and eight patients were included,comprised of 86 BAV and 122 TAV patients. Five,4,3,2,and 1-year MDCT follow-ups were achieved in 7,9,30,46,and 116 patients. The ascending aortic diameter was significantly increased after TAVR in both BAV group(43.7±4.4 mm vs. 44.0±4.5 mm;P<0.001) and TAV group(39.1±4.8 mm vs. 39.7±5.1 mm;P<0.001). However,no difference of ascending aortic dilatation rate was found between BAV and TAV group(0.2±0.8 mm/year vs. 0.3±0.8 mm/year,P=0.592). Multivariate linear regression revealed paravalvular leakage(PVL) grade was independently associated with ascending aortic dilatation rate in the whole population and BAV group,but not TAV group. No aortic events occurred during follow-ups.CONCLUSION: Ascending aortic size continues to grow after TAVR in BAV patients,but the dilatation rate is mild and comparable to that of TAV patients. PVL grade is associated with ascending aortic dilatation rate in BAV patients post-TAVR. 展开更多
关键词 TRANSCATHETER AORTIC VALVE REPLACEMENT AORTIC DILATATION BICUSPID AORTIC VALVE
在线阅读 免费下载
NOV 240 HEX型泥浆泵液力端常见失效分析 预览
2
作者 魏松 《机械工程师》 2019年第2期97-99,共3页
通过对新型NOV 240 HEX泥浆泵液力端常耗配件缸套、活塞、阀及阀座在实际运行中的失效问题进行分析,总结这些常耗配件的失效原因,提出相应的针对性措施。在以后的生产作业中延长其使用寿命,降低平均无故障间隔时间,降低材料使用成本,提... 通过对新型NOV 240 HEX泥浆泵液力端常耗配件缸套、活塞、阀及阀座在实际运行中的失效问题进行分析,总结这些常耗配件的失效原因,提出相应的针对性措施。在以后的生产作业中延长其使用寿命,降低平均无故障间隔时间,降低材料使用成本,提高经济效益。 展开更多
关键词 泥浆泵 缸套 活塞 阀座
在线阅读 下载PDF
Clinical Application of Bioprosthesis in China:Current Status and Future 预览
3
作者 Yin WANG Wei-wei JIANG Nian-guo D0NG 《当代医学科学(英文)》 SCIE CAS 2019年第4期523-525,共3页
China is one of the countries which have a high incidence of heart valvular disease,but the use of biological valve is limited in China before because the majority of patients are young patients suffering from rheumat... China is one of the countries which have a high incidence of heart valvular disease,but the use of biological valve is limited in China before because the majority of patients are young patients suffering from rheumatic heart disease.The biological valve has a good application prospect in China.On the one hand,the new generation of biological valves have been significantly improved in the aspects of anti-calcification treatment,anti-metabolism,material quality control,valve frame mechanics design,and leaflet sewing technology,and the application effect is improved;on the other hand,surgeons should adapt to the new concept changes,and correctly understand and rationally apply biological valves,master valve repair,atrial fibrillation ablation and other techniques,combined with interventional,minimally invasive techniques,etc.,according to the specific conditions of the disease and choose the surgery type to ensure the patients5 long-term life quality. 展开更多
关键词 BIOLOGICAL VALVE VALVE SURGERY CLINICAL application China
在线阅读 下载PDF
污水处理厂方形闸板阀维护与保养 预览
4
作者 李远 《冶金动力》 2019年第7期68-69,共2页
鞍钢西部污水处理厂进水闸板阀及南大沟防汛防洪闸板阀已连续使用20年,普遍存在阀板与滑道间隙不均,齿轮箱积液锈蚀的现象,增加了维护保养难度和安全风险。经过现场多次检修论证,通过调节阀门与滑道间隙,齿轮箱选用高弹性耐油密封胶的方... 鞍钢西部污水处理厂进水闸板阀及南大沟防汛防洪闸板阀已连续使用20年,普遍存在阀板与滑道间隙不均,齿轮箱积液锈蚀的现象,增加了维护保养难度和安全风险。经过现场多次检修论证,通过调节阀门与滑道间隙,齿轮箱选用高弹性耐油密封胶的方式,可有效解决阀门故障,延长阀门使用寿命。 展开更多
关键词 阀门 闸板阀维护 齿轮箱
在线阅读 下载PDF
海南木色湖供水管网水锤分析及防护 预览
5
作者 陈斌 《中国市政工程》 2019年第4期60-62,67,117,118共6页
水锤会对供水管网带来危害,尤其在长距离、高扬程、起伏变化较大的供水管道工程中。在水力过渡过程中,管道内极易出现负压或压力降到饱和蒸汽压以下而导致水柱分离。当分离开的水柱重新弥合时,会出现水锤特征的断流弥合水锤,从而对供水... 水锤会对供水管网带来危害,尤其在长距离、高扬程、起伏变化较大的供水管道工程中。在水力过渡过程中,管道内极易出现负压或压力降到饱和蒸汽压以下而导致水柱分离。当分离开的水柱重新弥合时,会出现水锤特征的断流弥合水锤,从而对供水管道、阀件造成严重破坏。以海南屯昌县木色湖风景区环湖路供水管道工程设计为例,通过计算机模拟分析各种工况下的供水管道内的水锤情况,根据分析结果复核供水管道及阀件的承压能力,确定关阀要求并增加相应的水锤防护措施,确保供水管道安全运行。 展开更多
关键词 供水管道 阀门 水锤 超压泄压阀
在线阅读 下载PDF
Successful minimal approach transcatheter aortic valve replacement in an allograft heart recipient 19 years post transplantation for severe aortic stenosis:A case report 预览
6
作者 Sravani Avula Sudhir Mungee Marco A Barzallo 《世界心脏病学杂志:英文版(电子版)》 2019年第8期209-212,共4页
BACKGROUND Aortic stenosis is one of the rare valvular complications in a transplanted heart.Over the past 8 years,transcatheter approach for aortic valve replacement(TAVR)has been slowly evolving to be the preferred ... BACKGROUND Aortic stenosis is one of the rare valvular complications in a transplanted heart.Over the past 8 years,transcatheter approach for aortic valve replacement(TAVR)has been slowly evolving to be the preferred approach in these patient population when compared to the surgical approach.We report a second case in the United States with successful transfemoral minimal approach with minimal sedation for TAVR in a heart transplant recipient 19 years post transplantation for severe symptomatic calcified aortic stenosis.CASE SUMMARY We present a case of 73-year-old male who has undergone successful minimal approach transcatheter aortic valve replacement in an allograft heart.Patient had received orthotopic heart transplantation 19 years ago for non-ischemic cardiomyopathy.Follow up transthoracic echocardiograms as per routine protocol did not show any aortic valve disease until 15 years post transplantation.Aortic valve was noted to be mildly sclerotic at that time and gradually progressed to severe symptomatic aortic stenosis over the next 4 years.Patient had complaints of worsening shortness of breath that limited his functional capacity.Overall his post heart transplantation period has been mostly uneventful except for allograft non occlusive vasculopathy and aortic stenosis.His Society of Thoracic Surgery risk score was 12.205%and he was considered to be a high-risk surgical candidate by surgeon.Decision was made to undergo transcatheter aortic valve replacement.CONCLUSION With the improved survival of these patients,we think it is time to look intopathophysiology of valvular disease in transplant heart recipients.Some other unanswered questions include,underlying donor and recipient risk factors for valvular diseases in heart transplant recipients. 展开更多
关键词 Transcatheter AORTIC VALVE REPLACEMENT HEART transplant MINIMAL APPROACH VALVE REPLACEMENT Severe AORTIC stenosis Case report
在线阅读 免费下载
两种型号青光眼阀植入难治性青光眼的疗效对比
7
作者 曾凤 卢亚梅 +3 位作者 周元清 陈永铃 刘佳 周致炎 《中华眼外伤职业眼病杂志》 2019年第7期518-523,共6页
目的比较FP7型与FP8型Ahmed青光眼阀(AGV)植入术治疗成人难治性青光眼的效果。方法回顾性分析2015年5月至2019年2月40例成人难治性青光眼的临床资料。患者随机分为两组,25例(25眼)行FP7 AGV植入术,15例(15眼)行FP8 AGV植入术。术后随访1... 目的比较FP7型与FP8型Ahmed青光眼阀(AGV)植入术治疗成人难治性青光眼的效果。方法回顾性分析2015年5月至2019年2月40例成人难治性青光眼的临床资料。患者随机分为两组,25例(25眼)行FP7 AGV植入术,15例(15眼)行FP8 AGV植入术。术后随访12个月。对比两组术前、术后眼压、视力、成功率、并发症及术后用药情况。结果两组术后各时间点平均眼压明显低于术前(P<0.05)。术后1天,FP7组眼压下降低于FP8组(t=-4.761,P<0.01),余时间点两组间眼压差异均无统计学意义(P>0.05);两组术后各时间点抗青光眼用药数量较术前均明显减少,差异均有统计学意义(P<0.05);术后各时间点两组平均抗青光眼药物数量差异无统计学意义(P>0.05)。两组术后12个月手术成功率、视力提高率和并发症发生率比较,差异均无统计学意义(P>0.05)。结论FP7和FP8 AGV植入术在降低眼压、保护视力、并发症和依赖青光眼药物量等方面效果相似,成功率也相当。在成人结膜下空间不足的情况下使用FP8 AGV是一个安全、有效的选择。 展开更多
关键词 青光眼 难治性 成人 青光眼 Ahmed 疗效
Prediction of short-term mortality after valve surgery
8
作者 Liu-Jia-Zi Shao Fu-Shan Xue +1 位作者 Rui-Juan Guo Li Zheng 《中华医学杂志:英文版》 SCIE CAS CSCD 2019年第5期624-625,共2页
To the Editor: In a single-center perspective study by Chen et al[1] determining the risk factors and predictors of shortterm mortality after valve surgery, multivariate logistic regression analysis showed that pre-op... To the Editor: In a single-center perspective study by Chen et al[1] determining the risk factors and predictors of shortterm mortality after valve surgery, multivariate logistic regression analysis showed that pre-operative New York Heart Association functional class 4. 展开更多
关键词 SHORT-TERM MORTALITY VALVE SURGERY RISK FACTORS
Analytical analysis of single-stage pressure relief valves
9
作者 Sven Osterland Jurgen Weber 《机电液工程学报》 2019年第1期1-2,共2页
The article presents an explicitly straightforward formulation of the stationary and dynamic behaviour of a pressure relief valve (PRV). This includes an analytical solution for the static p-Q-characteristic, the step... The article presents an explicitly straightforward formulation of the stationary and dynamic behaviour of a pressure relief valve (PRV). This includes an analytical solution for the static p-Q-characteristic, the step and harmonic response and a stability criterion using elementary operations only. It also mathematically proves the intrinsic connection between the gradient of the static p-Q-characteristic and the stability. Thus, the new method offers four main advantages. 展开更多
关键词 SINGLE-STAGE PRESSURE RELIEF valves PRESSURE RELIEF VALVE (PRV) STATIC p-Q-characteristic
核级不锈钢阀门密封唇焊维修质量控制 预览
10
作者 陈英杰 丁礼俊 +2 位作者 张鸿泉 吴小锋 左智成 《电焊机》 2019年第4期121-126,共6页
综合介绍核级不锈钢阀门密封唇焊的典型缺陷及成因,对影响焊接质量的重要维修工序进行了失效分析,制订了密封唇焊切割、结合面研磨、部件清洁及检查、阀体阀盖装配、焊接及焊后检查等维修关键工艺和质量控制技术要点,提出了在核电现场... 综合介绍核级不锈钢阀门密封唇焊的典型缺陷及成因,对影响焊接质量的重要维修工序进行了失效分析,制订了密封唇焊切割、结合面研磨、部件清洁及检查、阀体阀盖装配、焊接及焊后检查等维修关键工艺和质量控制技术要点,提出了在核电现场进行阀门密封唇焊维修的后续改进方向。 展开更多
关键词 阀门 密封唇焊 结合面 间隙 根部裂纹
在线阅读 下载PDF
石油天然气工业常用阀门标准应用要点分析与对比 预览
11
作者 魏涛 董姝妙 全本军 《石油化工设备》 CAS 2019年第3期45-51,共7页
国际通用阀门标准种类繁多,其中适用于石油天然气工业的阀门标准以ASME标准和API标准为主。探讨了ASME B16.34、ASME B16.5、ASME B16.10和API 6D这4种常用的阀门标准在确定阀门内径尺寸、阀门壁厚和压力等级、阀门法兰的尺寸和密封面... 国际通用阀门标准种类繁多,其中适用于石油天然气工业的阀门标准以ASME标准和API标准为主。探讨了ASME B16.34、ASME B16.5、ASME B16.10和API 6D这4种常用的阀门标准在确定阀门内径尺寸、阀门壁厚和压力等级、阀门法兰的尺寸和密封面形式、阀门结构长度、阀门材料及阀座形式等方面的具体应用,以及各标准在确定阀门尺寸、压力温度等级等要素上的异同,可为阀门设计和选用过程中各标准的准确应用提供参考。 展开更多
关键词 阀门 ASME标准 API标准 应用 分析 对比
在线阅读 下载PDF
阀门用14Cr17Ni2钢回火脆性研究
12
作者 陈黎明 《阀门》 2019年第2期20-21,23共3页
分析了奥氏体化温度以及回火冷却方法对14Cr17Ni2钢回火脆性的影响,通过采用不同试验材料相同热处理工艺及同一试验材料不同奥氏体化温度得出的试验结果,给出了降低14Cr17Ni2钢回火脆性的奥氏体化温度和回火处理工艺方法。
关键词 阀门 马氏体钢不锈钢 热处理缺陷 高温回火脆性 奥氏体化温度
阀件安装位置对管道应力状态影响的研究 预览
13
作者 蒋保胜 张艺凡 +2 位作者 时兴洪 贺禹 杨仲卿 《江西建材》 2019年第1期94-96,共3页
现代管道需要使用大量阀件进行调节,由于阀件安装位置的不确定性,使得管道应力状态受到的影响难以确定。CAESARⅡ软件已被用于对阀件安装位置对管道应力状态产生的影响进行研究,得出结论:随着阀件由管道中部向端部靠拢,管道最大应力值... 现代管道需要使用大量阀件进行调节,由于阀件安装位置的不确定性,使得管道应力状态受到的影响难以确定。CAESARⅡ软件已被用于对阀件安装位置对管道应力状态产生的影响进行研究,得出结论:随着阀件由管道中部向端部靠拢,管道最大应力值先上升后下降;挠度、Z向角位移逐渐减小,且减小的趋势随着阀件偏离中部的程度增大逐渐增大;在一定距离时阀件对管道应力状态产生的附加影响将会被抵消,继续缩小距离会进一步优化管道应力状态。 展开更多
关键词 管道 应力状态 阀件 安装位置
在线阅读 下载PDF
一种简易小通径阀盖毛坯粗加工设备
14
作者 谢海勇 谢海龙 +3 位作者 金春 陈章伟 徐华丰 许卫兵 《阀门》 2019年第2期22-23,共2页
分析了阀门阀盖毛坯的打磨及粗加工方式,介绍了一种简易的阀盖毛坯打磨铣面粗加工设备,该机构装置已获国家专利(专利号:ZL201610500616. 4),并对简易加工设备提出了圆桶式连接板结构增强其稳定性的改进方法。
关键词 阀门 阀盖 毛坯 打磨铣面 加工设备
虚拟手交互中约束类物体操作研究 预览
15
作者 邹俞 晁建刚 林万洪 《计算机工程与应用》 CSCD 北大核心 2019年第9期168-177,共10页
虚拟手技术是虚拟现实技术中的一种交互方式,是指通过手势识别技术将人的真实手映射到虚拟环境中并与虚拟物体进行交互操作的人机交互方式。主要应用于虚拟训练、虚拟手术和虚拟装配等领域。对虚拟手交互的约束类对象进行了研究,提出了... 虚拟手技术是虚拟现实技术中的一种交互方式,是指通过手势识别技术将人的真实手映射到虚拟环境中并与虚拟物体进行交互操作的人机交互方式。主要应用于虚拟训练、虚拟手术和虚拟装配等领域。对虚拟手交互的约束类对象进行了研究,提出了基于运动学的约束类物体操作方法,解决了阀门类有约束物体交互中虚拟手姿态不真实、操作不可控的问题。设计实验验证了基于运动学的方法能以符合实际操作的效果完成虚拟现实系统中的操作任务,可以应用到虚拟训练、虚拟装配等仿真平台。 展开更多
关键词 虚拟手 运动学 约束 阀门 旋转
在线阅读 下载PDF
核级阀门阀体密封面铁基合金堆焊工艺
16
作者 刘世辉 吴广坤 +1 位作者 郭鹏 马俊势 《阀门》 2019年第1期19-21,共3页
分析了核级手动阀门阀体密封面堆焊铁基合金时出现质量问题的原因,介绍了改变堆焊工艺参数和评估工艺稳定性后提出的阀门堆焊层质量控制措施。
关键词 核电站用阀 阀门 阀体 密封面 堆焊 铁基合金 质量控制
阀门用1Cr17Ni2钢热处理工艺优化
17
作者 刘春明 李宁 徐斌福 《阀门》 2019年第1期22-23,共2页
研究了1Cr17Ni2钢热处理后的微观显微组织构成,测试了不同成分1Cr17Ni2钢力学性能,论述了合理的优化热处理方法及控制材料成分可以获得优良的1Cr17Ni2钢微观金相组织和良好的力学性能。
关键词 阀门 材料 微观显微组织 Δ铁素体 力学性能 成分优化
铁道车辆液压减振器油液热平衡研究 预览
18
作者 廖津津 倪文波 王雪梅 《机械》 2019年第9期46-50,共5页
温度是衡量减振器在不同工况下安全状态的重要指标,研究减振器温度变化规律对减振器的散热性能设计具有重要意义。在CFD软件FLUENT中建立某减振器油液动网格模型,模拟了活塞周期性运动以及补偿阀的单向流通,仿真得到减振器油液的瞬态温... 温度是衡量减振器在不同工况下安全状态的重要指标,研究减振器温度变化规律对减振器的散热性能设计具有重要意义。在CFD软件FLUENT中建立某减振器油液动网格模型,模拟了活塞周期性运动以及补偿阀的单向流通,仿真得到减振器油液的瞬态温度场。仿真结果表明,减振器底阀区域和活塞区域温度上升明显,减振器温度由内向外扩散,减振器达到热平衡状态。随后进行了减振器热平衡温度台架试验,仿真结果与试验结果较为吻合。 展开更多
关键词 FLUENT 温度 动网格 减振器
在线阅读 下载PDF
铸锻阀门承压壳体裂纹分析与处理
19
作者 陆文斌 《阀门》 2019年第2期35-37,共3页
探讨了铸锻阀门承压壳体裂纹产生的过程和缺陷形式,分析了阀门壳体铸锻件裂纹产生的原因和机理,给出了防止阀门铸锻件产生裂纹缺陷需要注意的工艺规程和操作方法。
关键词 阀门 承压件 热加工 裂纹 缺陷检测
阀门部件冷装配与热装配工艺
20
作者 邢懿 郁春琳 吴春豪 《阀门》 2019年第2期42-45,共4页
介绍了阀门部件冷装配工艺和热装配工艺的操作流程和注意事项,并给出了每一种装配工艺的具体方案。